+INSTRUCTIONS
SIGNAL OVERLAP
The transmission signals are
measured and analyzed by the +.
If several transmission signals are
received and these transmission
signals are transmitting at the same
time then a signal overlap occurs.
The signals overlap and can no
longer be technically distinguished.
In the worst cases, this can last for
several seconds.
This situation is illustrated without
a direction arrow (e.g.” and
 signals).
You must wait until the signal over-
lap period has passed before you
continue your search.
PHOTO Klaus Fengler
 Sec
AUTOMATIC TRANSMISSION SWITCH OVER
In the event of a SECONDARY AVALANCHE
to which you fall victim (with your device in
search mode), the + automatically switches
to transmission mode after  minutes of non-
movement. This is indicated by a -second
warning tone.
This makes it possible for you to also be found
if buried in an avalanche while searching.
OX-GAL-3+-BUCH-vh.indd 41 06.06.13 15:26

Other manuals for Ortovox 3+

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ortovox 3+ and is the answer not in the manual?

Ortovox 3+ Specifications

General IconGeneral
Frequency457 kHz
Number of Antennas3
Marking FunctionYes
Multiple Burial IndicationYes
Operating Temperature-20°C to +45°C
Digital Search Strip Width40 m
WaterproofYes
Battery Life250 hours in send mode
Weight210 grams (including battery)