Page 32
Installation and Operation Manual - 2000
ENGLISH
APPLIANCE CLEARANCES (INSTALLATION
WITH SINGLE WALL PIPE CONNECTOR)
APPLIANCE CLEARANCES (INSTALLATION
WITH DOUBLE WALL PIPE CONNECTOR)
Canada USA Canada USA
A 14 ½" (368 mm) 11" (279 mm) A 6" (152 mm) 6" (152 mm)
B 17" (432 mm) 16" (406 mm) B 17" (432 mm) 16" (406 mm)
C 10" (254 mm) 10" (254 mm) C 7" (178 mm) 7" (178 mm)
K 48" (122 cm) 48" (122 cm) K 48" (122 cm) 48" (122 cm)
L 84" (213 cm) 84" (213 cm) L 84" (213 cm) 84" (213 cm)
If the above clearances are met, then the distances measured from the flue outlet will be:
DISTANCES
1
FROM PIPE CONNECTOR WITH
SINGLE WALL PIPE CONNECTOR
DISTANCES
1
FROM PIPE CONNECTOR WITH
DOUBLE WALL PIPE CONNECTOR
Canada USA Canada USA
D 18" (457 mm) 14 ½" (368 mm) D 9 ¼" (235 mm) 9 ¼" (235 mm)
E 26 ½" (673 mm) 25 ½" (648 mm) E 26 ¼" (667 mm) 25 ¼" (641 mm)
F 19 ¾" (502 mm) 19 ¾" (502 mm) F 16 ½" (419 mm) 16 ½" (419 mm)
7.2.1 Clearances with heat shield AC02710
Note that to reduce the clearances of an appliance using a single wall pipe connector, the use
of a heat shield certified with the single wall pipe connector to be used as close as 6" from
combustible materials must be used. Only in this case, the same clearances as a certified
double wall pipe connector can be used.
APPLIANCE CLEARANCES (INSTALLATION
WITH DOUBLE WALL PIPE CONNECTOR)
DISTANCES
1
FROM DOUBLE WALL PIPE
CONNECTOR
Canada USA Canada USA
A 3" (76 mm) 3" (76 mm) D 6 ¼" (159 mm) 6 ¼" (159 mm)
B 4" (102 mm) 4" (102 mm) E 13 ¼" (337 mm) 13 ¼" (337 mm)
C 3" (76 mm) 3" (76 mm) F 12 ½" (318 mm) 12 ½" (318 mm)
K 48" (122 cm) 48" (122 cm)
L 84" (213 cm) 84" (213 cm)
1
The pipe distances listed in this table refer to the distances obtained when the stove is installed in accordance with the appliance clearances above
mentioned.