2200InstallationandOperationManual
______________________________________________________________________________35
8.2.2 FACTORY‐BUILT METAL CHIMNEYS
INMOBILEHOMES
For use in a mobile home, this stove is to
be connected to a 6” in diameter double
wall factory built chimney conforming to
CAN/ULC‐S629, Standards for 650°C
Factory‐built chimney. The total length of
the flue system should be at least 12 feet
including elbows, from the top of the
stove.
To maintain an effective vapour barrier,
insulation and waterproof at the chimney
and outside flue pipe, install a mobile
home roof flashing and seal it with
silicone.
8.2.3 MASONRYCHIMNEYS
The stove may also be connected to a
masonry chimney, provided the chimney
complieswiththeconstructionrulesfound
in the building code enforced locally. The
chimneymusthaveeitheraclay liner or a
suitably listed stainless steel liner. If the
masonry chimney has a square or
rectangular liner that is larger in cross
sectional area than a round 6” flue, it
should be relined with a suitably listed 6”
stainless steel liner. Do not downsize the
flue to less than 6” unless the venting
system is straight and exceeds 25 feet in
height. When passing through a
combustible wall, the use of an insulated
listedthimbleisrequired.

Table of Contents