Please Note: If the video source requires ground termination, a 75Ω termination resistor
may be inserted using the switch between the Sync Reference connectors.
Generally, termination is required if RADAR II is the last device (or only
device) in the sync chain, and if there is no downstream device connected
to Sync Reference Out.
Do not insert the termination resistor if Loop Through is configured, and
any device is connected to Sync Reference Out!
5.2.4 Digital Word Clock Connections
If using RADAR II with an external digital word clock source, connect this source
to the WORD SYNC In connector. If a loop-through is required, you may connect
the WORD SYNC Out BNC to the device requiring the same digital word clock.
Please refer to the above note regarding termination for digital Word Clock.
E X T E R N A L S Y N C H R O N I Z A T I O N F E A T U R E S 5-7