LINE 1 TO PREAMP: LINE 1 is active, but routed through the mic preamp, post-transformer.
LINE 1 signal is available on PREAMP OUT.
INPUT control - Sets the level of the input signal. 5 is unity.
FILT switch - Engages the filter circuit into the main/SAT signal path.
EQ switch - Engages the equalizer circuit into the main/SAT signal path.
COMP switch - Engages the compressor circuit into the main/SAT signal path.
FILTERS
HPF PEAK control - Resonance control for the high pass filter, will self oscillate at settings >8.
HIGH PASS Hz control - Sets the frequency of the high pass filter.
LPF PEAK control - Resonance control for the low pass filter, will self oscillate at settings >8.
LOW PASS KHz control - Sets the frequency of the low pass filter.
FLOATING switch (8755DM version) - This switch only has effect when ‘MIC’ is selected
on the input toggle. Routes the balanced line input through the preamplifiers directly (not
through the transformers). This also allows a balanced line input to be controlled (and driven)
with the GAIN controls at the front of the signal path. Due to the design, the bypass signal
has to come from after the preamplifiers, so if the GAIN controls are high, when
entering bypass mode the levels can be extremely high.
CURVE switch - Curve shapes the distortion response of the unit, the default mode being on
(toggle right, LED on). This allows the power of the lower fundamentals to be maintained, but
there are instances where more distortion is desired in the low end, in which case CURVE off
may be more suitable.
Copyright © 2018, Overstayer Recording Equipment, Inc..
All rights reserved. All features and specifications are subject to change without notice.