EasyManua.ls Logo

oxycom CABIN 400 - 6 Technical Specifications; Technical Details; Water Quality

Default Icon
30 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
00010605 B 24
6 TECHNICAL SPECIFICATIONS
6.1 Technical details
Note
All specifications are indicative only and subject to change without
notice.
6.2 Water quality
The CABIN 400 requires the use of drinking water only. The use of dirty water or water
from pools or lakes is forbidden. If in doubt about water quality, ask the camping site
manager or the local water authority if the water supply meets the following
specifications. The table shows the parameters of the drinking water guidelines that
apply to the CABIN 400.
Ta b l e 2 CABIN 400 technical details
Power consumption max. 240 W
Weight approx. 24kg
12 V power supply requirement approx. 4 A. (only when the pump
motor is running)
Maximum air flow 400 m
3
per hour
OXYZONE circuit board fuse Glass fuse 5x20, 2 A., slow blow
Water reservoir connection box fuse Fuse ATO, 5 A., slow blow
Ta b l e 3 Water quality required for the CABIN 400
Parameter Max. value Unit Note
Chloride 150 mg/l Annual average
Conductivity (20ºC) 125 mS/m
Total hardness 18 °D mmol Ca
2+
plus Mg
2+