5. ELECTRICAL CONNECTIONS
Fig. 8
Receiver
Fan canopy
Outlet box
Wall control
Ceiling
REMEMBER -Turn off the power!
HI
MED
LOW
FAN OF F
LIGHT
OFF
ON
BLU
WH
WH WH
BLK
BLK
BLK
BLK
House
supply
wire
GRN
GROUND
GRN
If your junction box has a ground wire
(green or bare copper), connect the
transmitter's ground wire to it. Otherwise,
connect the transmitter ground wire
directly to one of the screws from the
outlet box.
Carefully tuck the connected wires
inside the junction box. Secure the
transmitter with the two screws provided.
Attach the face plate over the transmitter
with the two screws provided.
5. Put the receiver unit inside the canopy.
Proceed to Step 7 - Completing the
Installation.
NOTE: This unit is equipped with an
automatically learned type remote control.
There are no frequency switches on the
receiver and transmitter; the receiver unit
will automatically scan the frequency from
the wall control if any changes are made.
This unit has 65,000 different code
combinations.
Use the wire nuts supplied with your fan
when making connections. Secure the
connectors with electrical tape and make
sure there are no loose connections or wire
strands.
1. Make wire connections from the fan
to the wall control receiver unit. For this
step use the bundle of 3 wires on the
receiver. (Fig. 8)
Connect the BLACK fan wire to the
BLACK receiver wire.
Connect the BLUE fan wire to the
BLUE receiver wire.
Connect the WHITE fan neutral wire
to the WHITE receiver neutral wire.
2. Connect the wiring from the ceiling to
the receiver unit. (Use the 2 wire bundle
on the receiver.) Secure with supplied wire
nuts.
Connect the BLACK building
supply wire to the BLACK receiver
wire.
Connect the WHITE receiver neutral
wire to the WHITE building neutral wire.
Connect the COPPER building
ground wire to the GREEN fan ground
wire.
3. Connect the wiring from the wall
switch receptacle to wall transmitter unit.
Remove the existing wall plate and
switch from the wall junction box.
Connect one BLACK wire from the
wall to one BLACK wire (labeled "TO
FAN") from the wall transmitter.
Connect the other BLACK wire
(labeled "TO POWER SUPPLY")
from the transmitter to the remaining
BLACK wire from the wall (A/C
supply source).
NOTE: It may be necessary to bind
the house wires to the corresponding
receiver wires with electrical tape
before capping them with wire nuts.
This will prevent them from slipping
apart during the rest of the installation.
REV
Use ONLY wall controls approved by
OXYGEN. Use of unapproved wall
controls will cause unacceptable
humming noise, and avoids the fan
warranty.