Order new UV lamp
UV lamps can be purchased directly from Ozoneair. Use of parts other
than those supplied by Ozoneair will void any warranties.
WARNING! - It is important to replace the lamps
when they reach its lifetime limit. An old lamp having a
darkened glass surface has a risk of breaking and should
be replaced at advised time. Always replace both UV
lamps at the same time to ensure proper running of the
machine.
NOTE - The UV lamps shall be disposed in containers
intended for lamps containing mercury.
Cleaning of UV lamps
It is recommended to clean the UV lamps every 3-6 months. This is to
ensure that the UV light is emitted with full eect from the lamps.
For regular maintenance or if the quartz glass of the UV lamps becomes
stained, extract the lamp holder and clean the outside of the lamp with
a soft cotton towel and alcohol. Be careful not to touch the quarts glass,
use protection gloves or a cloth if needed. Fingerprints can inhibit the
lamps disinfection eect.
To install new
lamps, reverse the
process
Reset the UV count
by pressing silver
and daily button
simultaneously
until “Replace UV”
has disappeared.
NOTE - The remote contains a CR2025 battery. New
batteries can be bought at your local hardware store.
Remove/insert HEPA filter
HEPA filter
After approximately 6 months or 5000 hours of use, the HEPA filter
needs to be replaced to maintain an accurate cleaning level and for the
machine to run optimally.
15
EN
Pull the fabric
straight out to
detach the outer
protection.
Remove the filter.
Insert a new filter,
ensure the filter is
inserted the right
way.
Order new HEPA filters
HEPA filters can be purchased directly from Ozoneair. Use of parts other
than those supplied by Ozoneair will void any warranties.
NOTE - There is a metal prefilter attached to the outer
protection to remove larger dust particles and hair.
This can be cleaned with a vacuum cleaner or by gently
washing with detergent and water.
Reset the filter
count by pressing
silver and
eect button
simultaneously
Attach the outer
protection.
14
EN
Remove/insert UV lamps