PAB Fire Compact
The helmet meets the requirements of Directive 89/686/CEE and is certied
according to EN 443:2008, EN 14458:2004, EN 166:2004 and Marine Equipment
Directive (MED) standards.
Helmet – Standards, Directives and Markings
Certication
agency
CSI S.p.A, Viale Lombardia 20, 20021 Bollate (MI), Italy,
Notied Body No.: 0497
Directives and
Standards
89/686/EEC Personal Protection Equipment
EN 443:2008 “Helmets for reghting in buildings and other structures “
Marking A3b Indicates the protection zone assured by the helmet
(protects dome of the skull and the frontal chin region)
*** Indicates protection at low temperatures down to -30°C
E2 Indicates the electrical insulation of the wet helmet
C Indicates resistance to liquid chemicals (Sulphuric acid,
Sodium hydroxide, p-Xylene, Butan-1-ol, n-Heptane)
Certication
agency
Det Norske Veritas GL AS, Norway, Notied Body No.: 0575
Directives and
Standards
MED Marine Equipment Directive
Marking “Wheel mark” Meets Council Directive 96/98/EC on Marine Equipment
CERTIFICATIONS AND TECHNICAL SPECIFICATIONS