EasyManua.ls Logo

Pacific hydrostar 69305 - User Manual

Pacific hydrostar 69305
12 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Read this material before using this product.
Failure to do so can result in serious injury.
SAVE THIS MANUAL.
Copyright
©
2011 by Harbor Freight Tools
®
. All rights reserved.
No portion of this manual or any artwork contained herein may be reproduced in
any shape or form without the express written consent of Harbor Freight Tools.
Diagrams within this manual may not be drawn proportionally. Due to continuing
improvements, actual product may differ slightly from the product described herein.
Tools required for assembly and service may not be included.
When unpacking, make sure that the product is intact
and undamaged. If any parts are missing or broken,
please call 1-800-444-3353 as soon as possible.
Save This Manual Keep this manual for the safety warnings and precautions, assembly, operating,
inspection, maintenance and cleaning procedures. Write the product’s serial number in the back of the manual
near the assembly diagram (or month and year of purchase if product has no number). Keep this manual and
the receipt in a safe and dry place for future reference.
Owners Manual & Safety Instructions
Visit our website at: http://www.harborfreight.com
Email our technical support at: tech@harborfreight.com
SHALLOW WELL
PUMP
ITEM 69302 / 69305
ITEM 69305ITEM 69302

Questions and Answers

  • R
    roger92Aug 14, 2025
    Why won't my Pacific hydrostar 69305 Water Pump start?
    • A
      Andrea PetersenSep 12, 2025
      Your Pacific hydrostar Water Pump might not be starting due to several reasons: * There could be no power. Check the connections, breaker, or fuse. * The pressure switch might be disconnected. Check the gauge. * The thermal protection may have cut out. Allow the pump to cool. * The impeller could be blocked. Free the impeller.
  • J
    Joshua BakerAug 20, 2025
    What to do if my Pacific hydrostar Water Pump does not shut-off?
    • K
      Keith FryAug 21, 2025
      If your Pacific hydrostar Water Pump isn't shutting off, here are a few potential causes: * The pressure switch contacts may be welded together. Have the pressure switch replaced by a qualified technician. * A fixture (toilet, faucet, etc.) might be open or leaking. Close or repair the fixture. * The impeller could be clogged. Clean the impeller. * The tank bladder pressure may be too low. Inflate to 23 PSI. * There may be pipeline leakage. Repair the pipeline. * The foot/check valve might be leaking water back to the well. Replace the foot/check valve.
  • A
    Alicia BlackAug 25, 2025
    Why is my Pacific hydrostar Water Pump operating but not discharging water?
    • M
      melissafarleyAug 25, 2025
      If your Pacific hydrostar Water Pump is running but not discharging water, it could be due to these reasons: * The pump might not be primed. Prime the pump. * The lift height could be exceeded. Reduce the lift height. * The inlet tube may not be submerged. Submerge the inlet. * There might be air in the suction pipe. Check the pipe and seals. * The inlet screen could be clogged. Clean the screen.
  • D
    Daniel StewartAug 27, 2025
    Why does my Pacific hydrostar 69305 motor overheat often?
    • J
      James PetersonAug 27, 2025
      If your Pacific hydrostar Water Pump motor overheats frequently, it could be due to: * An extension cord that is too long or has a wire size that is too small. Eliminate the use of the extension cord, or use a shorter/heavier gauge cord. * The pump cycling too often. The cut-in and cut-out pressure may be set too close together. Have the pressure switch adjusted by a qualified technician.
  • J
    Jean JohnsonAug 31, 2025
    Why is there only a low volume of water flowing from my Pacific hydrostar 69305 Water Pump?
    • B
      Brittney BarnesAug 31, 2025
      A low volume of water flowing from your Pacific hydrostar Water Pump could be caused by: * An inlet pipe that is too small. Increase the pipe diameter. * Liquid that is too dirty. Clean the screen frequently. * Lifting height being exceeded. Reduce the lifting height. * The tank’s rubber bladder being under-inflated. Inflate to 23 PSI. * Piping corroded, causing friction. Replace the piping, using plastic where possible.
  • R
    Rebecca PattonSep 3, 2025
    Why is the water from my Pacific hydrostar 69305 full of bubbles at the outlet?
    • R
      Ronald OrtizSep 3, 2025
      If the water from your Pacific hydrostar Water Pump is full of bubbles, it could be due to: * Pumping bubbles temporarily as air is purged after initial setup. This is a temporary self-remedying issue. * A leak in the suction side of the pump system. Check for and fix leaks. * The well being gaseous. Install a sleeve in the well. * The water level being below the suction inlet of the foot valve. Lower the suction line into water and re-prime. If the water is deeper than the Maximum Suction Lift, then a deep well pump may be needed.
  • M
    monica38Sep 6, 2025
    What to do if my Pacific hydrostar 69305 will not hold prime?
    • S
      sharpnicholasSep 6, 2025
      If your Pacific hydrostar Water Pump will not hold prime, it may be because: * A foot/check valve is not installed in the suction line. Install a foot and check valve in the suction line. * The foot/check valve leaks water back to the well. Replace the foot/check valve.
  • J
    Jeffrey LewisSep 9, 2025
    Why does my Pacific hydrostar 69305 tank bladder will not hold pressure?
    • J
      Jennifer BryantSep 9, 2025
      If the tank bladder of your Pacific hydrostar Water Pump won't hold pressure, it could be because: * The air inlet valve is leaking. Check the air tank for leaks using soapy water and replace the bladder if needed. * The bladder is broken. Replace the bladder.
  • J
    Jacqueline LewisNov 16, 2025
    What to do if my Pacific hydrostar Water Pump motor runs, but water is not pumping?
    • G
      Gerald ShawNov 17, 2025
      If your Pacific hydrostar Water Pump motor is running but not pumping water, consider the following: * The pump may not be properly primed. Prime the pump by pouring clean water into the Priming Inlet. * There might be air leakage. Check all pipes and joints in the suction line for air leakage using soapy water. * The vertical lift could be too high. Reduce vertical lift to within specifications. * The water level might be below the suction inlet of the foot valve. Lower the suction line into water and re-prime. A deep well pump may be needed if the water is deeper than the Maximum Suction Lift. * The pipes could be frozen. Thaw the pipes, bury them below the freeze line, or insulate them. * The foot valve may be in dirt or sand. Raise the foot valve to a clean water level. * ...

Summary

Safety and Grounding Instructions

Electric Shock Prevention

Detailed instructions to prevent electric shock from improper grounding.

Specifications and Components

Technical Specifications

Model numbers, electrical ratings, flow, pressure, and height specifications.

Component Identification

Visual identification of pump parts for models 69302 and 69305.

Installation Guide

Power and Safety

Guidelines for safe electrical connections, socket requirements, and shock prevention.

Installation Considerations

Key factors for proper installation, including placement, water quality, and piping.

Operation Instructions

Priming and Starting Procedure

Step-by-step guide to priming the pump and initial operating checks before power connection.

Maintenance and Troubleshooting

Safety Precautions

Critical warning to disconnect power before performing any inspection, maintenance, or cleaning.

69302 Parts List

69302 Assembly Diagram

69305 Parts List

69305 Assembly Diagram

Limited 90 Day Warranty

Pacific hydrostar 69305 Specifications

General IconGeneral
BrandPacific hydrostar
Model69305
CategoryWater Pump
LanguageEnglish

Related product manuals