LMX SERIES™ OPERATION MANUAL
SECTION 8:
Remote Control Programming
Entire Contents Copyright 2018 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
LMX Series Power Source Operation Manual Page 331 of 463
SYSTem:COMMunicate:SERial:BITS
This command sets the number of data bits used for serial
communications. Available settings are 7 or 8
SYSTem:COMMunicate:SERial:BITS?
SYSTem:COMMunicate:SERial:SBITs
This command sets the number of stop bits used for serial
communications. Available settings are 1 or 2.
SYSTem:COMMunicate:SERial:SBITs?
SYSTem:COMMunicate:SERial:FLOWcontrol
This command sets the method of handshaking used for serial
communications. Available settings are Xon/Xoff or Hardware
SYSTem:COMMunicate:SERial:FLOWcontrol?
8.9.9 Communication USB Commands
SYSTem:COMMunicate:USB:VIRTualport[:ENABle]
This command enables USB device control using virtual comm driver.
SYSTem:COMMunicate:USB:VIRTualport[:ENABle]?