NICHE INSTALLATION
Final Installation
Mount light to
niche by tilting into bottom
lip and securing with screw
at top.
DO NOT
USE ELECTIC DRILL.
Install conduit to
power supply
6
400mm (MAX)
95mm (MIN)
22mm(MAX)
12mm (MIN)
140mm (STANDARD)
120mm (MIN)
Niche Depth
70mm(MAX)
50mm (MIN)
Pool Finish
Concrete Thickness
WATER LINE
Concrete reinforcing bars
Sealant
50mm MIN
Concrete
coverage
SOIL
CONCRETE