Ohjekirja Palax combi M 2004.1 En
29
9 Malfunctions and their remedy
Disturbance Cause
Remedy
The cross-cut saw-blade is
heavy on power and gets hot
.
1. The blade is dull.
2. Setting too small.
3. Too much resin in the
blade.
1. Sharpen the saw-blade.
2. Set the blade.
3. Clean the blade.
The saw-blade wobbles.
The cross-cut blade starts to
wobble after a short period of
working.
1. Impurities between the
flanges.
2. Setting too small, pre-
stressing faults.
Clean the flanges and the
blade.
Set the blade.
Pre-stress the blade.
The blade whines. 1. Too high speed, max.
1,500 r.p.m.
2. Root-crack at the tooth
Decrease the speed
Do not use, replace the
blade.
The saw-blade rotates in the
wrong direction.
Wrong phase-order. 1. Switch positions of two
phases.
The electric motor does not
start.
1. Emergency stop button
depressed.
2. Makes loud noise, but
does not start.
1. Reset the emergency
stop.
2. The fuse has blown,
replace it.
The motor stops several
times and the thermo-relay
trips.
1. The blade is dull.
2. Incorrect setting of the
thermo-relay.
1. Sharpen the saw-blade.
2. Re-adjust the thermo-
relay.
Whining sound during the
sawing operation and the
revolutions drop.
1. V-belts are slack. 1. Tighten the belts.
The Honda engine dies. 1. Out of fuel.
2. Oil level low.
1. Refuel
2. Top up engine oil.