EasyManua.ls Logo

Panasonic ADC0916H9E8 User Manual

Panasonic ADC0916H9E8
424 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
1
ENGLISH
SAFETY PRECAUTIONS
Read the following “SAFETY PRECAUTIONS” carefully before installation of Air-To-Water Hydromodule + Tank (here after referred to as “Tank Unit”).
Electrical works and water installation works must be done by licensed electrician and licensed water system installer respectively. Be sure to use the correct
rating and main circuit for the model to be installed.
The caution items stated here must be followed because these important contents are related to safety. The meaning of each indication used is as below.
Incorrect installation due to ignorance or negligence of the instructions will cause harm or damage, and the seriousness is classifi ed by the following indications.
Please leave this installation manual with the unit after installation.
WARNING
This indication shows the possibility of causing death or serious injury.
CAUTION
This indication shows the possibility of causing injury or damage to properties only.
The items to be followed are classifi ed by the symbols:
Symbol with white background denotes item that is PROHIBITED from doing.
Symbol with dark background denotes item that must be carried out.
Carry out test run to confi rm that no abnormality occurs after the installation. Then, explain to user the operation, care and maintenance as stated in
instructions. Please remind the customer to keep the operating instructions for future reference.
If there is any doubt about the installation procedure or operation, always contact the authorized dealer for advice and information.
WARNING
Do not use unspecifi ed cord, modifi ed cord, joint cord or extension cord for power supply cord. Do not share the single outlet with other electrical appliances. Poor
contact, poor insulation or over current will cause electrical shock or fi re.
Do not tie up the power supply cord into a bundle by band. Abnormal temperature rise on power supply cord may happen.
Keep plastic bag (packaging material) away from small children, it may cling to nose and mouth and prevent breathing.
Do not use pipe wrench to install refrigerant piping. It might deform the piping and cause the unit to malfunction.
Do not purchase unauthorized electrical parts for installation, service, maintenance and etc.. They might cause electrical shock or fi re.
Do not add or replace refrigerant other than specifi ed type. It may cause product damage, burst and injury etc.
Do not use the hot water produced by the Tank Unit for drinking or food preparation. It may cause illness to the user.
Do not place containers with liquids on top of the Tank Unit. It may cause Tank Unit damage and/or fi re could occurs if they leak or spill onto the Tank Unit.
Do not use joint cable for Tank Unit / Outdoor Unit connection cable. Use specifi ed Tank Unit / Outdoor Unit connection cable, refer to instruction
4
CONNECT
THE CABLE TO THE TANK UNIT and connect tightly for Tank Unit / Outdoor Unit connection. Clamp the cable so that no external force will be acted on the
terminal. If connection or fi xing is not perfect, it will cause heat up or fi re at the connection.
For electrical work, follow local wiring standard, regulation and this installation instruction. An independent circuit and single outlet must be used. If electrical
circuit capacity is not enough or defect found in electrical work, it will cause electrical shock or fi re.
For water circuit installation work, follow to relevant European and national regulations (including EN61770) and local plumbing and building regulation codes.
Engage dealer or specialist for installation. If installation done by the user is defective, it will cause water leakage, electrical shock or fi re.
This is a R410A model, when connecting the piping, do not use any existing (R22) pipes and fl are nuts. Using such same may cause abnormally high pressure
in the refrigeration cycle (piping), and possibly result in explosion and injury. Use only R410A refrigerant.
Thickness for copper pipes used with R410A must be 0.8 mm or more. Never use copper pipes thinner than 0.8 mm.
It is desirable that the amount of residual oil is less than 40 mg/10 m.
Required tools for Installation Works
1 Philips screw driver
2 Level gauge
3 Electric drill
4 Spanner
5 Pipe cutter
6 Reamer
7 Knife
8 Measuring tape
9 Megameter
10 Multimeter
11 Torque wrench
42 N•m (4.2 kgf•m)
58.8 N•m (5.8 kgf•m)
65 N•m (6.5 kgf•m)
117.6 N•m (11.8 kgf•m)
AIR-TO-WATER HYDROMODULE + TANK
ADC0916H9E8
Installation Manual
ACXF60-04180
1
4
ENGLISH ................1
ESPAÑOL ............. 31
ITALIANO ..............61
ACXF60-04180_EN ES IT.indb 1ACXF60-04180_EN ES IT.indb 1 11/17/2016 9:12:29 AM11/17/2016 9:12:29 AM

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Panasonic ADC0916H9E8 and is the answer not in the manual?

Panasonic ADC0916H9E8 Specifications

General IconGeneral
BrandPanasonic
ModelADC0916H9E8
CategoryHeat Pump
LanguageEnglish

Summary

Safety Precautions

General Safety Guidelines and Warnings

Covers essential safety precautions, warnings, and cautions for installation and operation.

Installation Space and Piping Preparation

Piping Connection Procedures

Drainage Systems and Cable Connections

Power and Communication Cable Connections

Guides on connecting power supply cables and communication cables to the Tank Unit.

Water Charging and Electrical Setup

System Water Charging Procedure

Procedure for filling the system with water and releasing air for both domestic hot water and heating/cooling circuits.

Test Run and Unit Maintenance

External Device Wiring and Cable Management

PCB and Component Wiring Details

Remote Controller Interface Overview

Remote Controller Layout and Functions

An overview of the remote controller's buttons, screen layout, and their respective functions for system operation.

Initial Power On and Basic Setup

Installer Setup Parameters

Optional PCB and Zone Configuration

Configures optional PCB connectivity, zone control, and sensor settings for system operation.

Heater, Anti-freeze, and Buffer Tank Configuration

Sets up heater capacity, anti-freezing function, and buffer tank connection for optimized performance.

Operation Setup Parameters

Heating and Cooling Operation Settings

Configures target water temperatures, outdoor temperatures, and temperature differences for heating and cooling operations.

Auto Mode and Tank Operation Settings

Sets automatic switching points between heating/cooling and configures tank operation parameters like time, temperature, and sterilization.

System Setup Parameters

Optional PCB Connectivity and Zone Setup

Configures optional PCB usage and defines zone/sensor settings for multi-zone control.

Heater, Anti-freeze, and Buffer Tank Setup

Sets heater capacity, anti-freezing function, and buffer tank connection for optimized system performance.

System Setup: Boiler and Solar Integration

System Setup: External Controls and Signals

System Setup: Compressor, Liquid, and Mode Switching

Operation Setup: Heating and Cooling Details

Heating Temperature Settings

Configures target water temperatures, outdoor temperatures, and temperature differences for heating operations.

Cooling Temperature Settings

Configures target water temperatures and temperature differences for cooling operations.

Operation Setup: Auto Mode and Tank Functions

Auto Mode Switching and Tank Operation Times

Sets automatic switching points between heating/cooling and configures tank operation parameters like time.

Tank Re-heat and Sterilization Settings

Configures tank re-heat temperature and sterilization cycles for hygiene and performance.

Service Setup Procedures

Pump and Dry Concrete Setup

Configures pump speed, pump down operation, and dry concrete curing process for service purposes.

Service and Maintenance Operations

Computer Connection for Service and Diagnostics

Instructions for connecting a computer via USB for advanced service functions and diagnostics.

Related product manuals