Note1) If CH0, CH2, CH4 and CH6 of the high-speed counter is set to the two-phase input, individual
input or incremental/decremental control input, the settings of CH1, CH3, CH and CH7 will be
invalid.
Note2) Only CH0 and CH2 are available for the reset input of the high-speed counter.
X6 for CH0 and X7 for CH2 can be allocated.
Note3) X4 to X7 can be used as the home input of the pulse output CH0 to CH3.
When using the home return function of the pulse output, always set the home input. In that
case, X4 to X7 cannot be set as the high-speed counter.
Note4) When using the pulse output/PWM output, the controller output settings must be specified.
The output that has been set to the pulse output/PWM output cannot be used as the normal
output.
Note5) If the same input has been set to the high-speed, pulse catch and interrupt input simultaneously,
the following precedence order is effective:
[High-speed counter] → [Pulse catch] → [Interrupt input]