I/O Points | 30 |
---|---|
Input Points | 16 |
Output Points | 14 |
Power Supply | 24V DC |
Program Memory | 32k steps |
High-speed Counter | 6 channels |
Data Memory | 12k words |
Communication Ports | RS232C, RS485 |
Operating Temperature | 0 to +55 °C |
Programming Language | Ladder Logic |
Output Type | Transistor |
Type | Programmable Logic Controller (PLC) |
Expansion Modules | Supported |
Lists AC and DC power supply specifications for various units.
Covers operating environment, static electricity, and heat discharge measures.
Covers AC power supply wiring, confirmation of voltage range, and isolation of power supply systems.
Provides guidelines and precautions for wiring input and output signals.
Covers safety precautions for system design, interlock circuits, emergency stop, start-up sequence, grounding, and output protection.
Explains the computer link function for communication between computers and PLCs.
Introduces MODBUS RTU protocol and its functions.
Introduces Ethernet communication using the AFPX-COM5 cassette.
Provides detailed specifications for the FP-X Analog Input Cassette (AD2).
Details specifications for the FP-X Analog Output Cassette (DA2).
Details specifications for the FP-X Analog I/O Cassette (A21).
Details specifications for the FP-X Thermocouple Cassette (TC2).
Details specifications for the FP-X RTD Cassette (RTD2).
Describes the F175 instruction for linear interpolation positioning control.
Explains the overview, input modes, and count methods for high-speed counters.
Introduces pulse output functions and instructions for Ry type.
Explains how to use passwords to prohibit program reading and writing.
Details the function to prohibit program uploading from the FP-X.
Introduces the sampling trace function for monitoring data.
Explains the self-diagnostic function and LED indicators on the control unit and expansion adapter.
Guides on troubleshooting common issues, including when the ERROR LED is flashing.
Provides troubleshooting steps when the ERROR LED is ON, indicating watchdog timer activation.
Guides on diagnosing output malfunctions by checking LEDs and wiring.
Provides troubleshooting steps for communication errors occurring via RS485.
Details troubleshooting steps for communication errors occurring via RS422.
Offers troubleshooting steps for communication errors occurring via Ethernet.
Covers types of operation errors like address, BCD, parameter, and over area errors.
Explains the operation and precautions of rewriting programs during RUN mode.
Explains how forced input/output operations are processed during RUN.
Lists general specifications including ambient conditions, voltage resistance, and insulation.
Lists power supply specifications for AC and DC power for various units.
Lists performance specifications for control units, expansion units, and cassettes.
Compares communication specifications for different interfaces and modes.
Explains system registers, special internal relays, and data registers for FP-X.
Provides a table of special data registers for FP-X, including their addresses, names, and descriptions.
Details self-diagnostic errors like CPU error, RAM error, and master memory errors.