15.1 Table of Specifications
15.1.1 General Specifications
Item
Description
Ambient temperature
0 to +55 °C
Storage temperature
40 to +70°C
Ambient humidity
10 to 95%RH (at25°C non-condensing)
Storage humidity
10 to 95%RH (at25°C non-condensing)
Break-
down
voltage
Note1)
Relay type
AC power supply
DC power supply
Between input terminal and output
terminal
Note4)
2300 V AC for 1
min.
Note2)
2300 V AC for 1
min.
Note2)
Between input terminals and power
supply/earth terminals
500 V AC for 1
min.
Note2)
Between output terminals and
power supply/earth terminals
2300 V AC for 1
min.
Note2)
Between cassette I/O terminal and
power supply/earth terminals
Note3)
500 V AC for 1
min.
Note2)
Between cassette I/O terminal and
input terminals
500 V AC for 1
min.
Note2)
Between cassette I/O terminal and
output terminals
2300 V AC for 1
min.
Note2)
2300 V AC for 1
min.
Note2)
Between communication cassette
RS485 and power supply/input/
output/earth terminals
Note3)
500 V AC for 1
min.
Note2)
500 V AC for 1
min.
Note2)
Between power supply terminal
and earth terminal
1500 V AC for 1
min.
Note2)
Transistor
type
Between input terminal and output
terminal
Note4)
500 V AC for 1
min.
500 V AC for 1
min.
Between input terminals and power
supply/earth terminals
2300 V AC for 1
min.
Note2)
Between output terminals and
power supply/earth terminals
Between cassette I/O terminal and
power supply/earth terminals
Note3)
Between cassette I/O terminal and
input/output terminals
500 V AC for 1
min.
Between communication cassette
RS485 and power supply/input/
output/earth terminals
Note3)
Between power supply terminal
and earth terminal
1500 V AC for 1
min.
Note2)
Insulation resistance
Note1)
Between input terminal and output
terminal
Note4)
100 M or more
(500 V DC
measured with a megohm-meter)
Between input terminals and power
supply/earth terminals
Between output terminals and
power supply/earth terminals
Between cassette I/O terminal and
power supply/earth terminals
Note3)
Between cassette I/O terminal and
input/output terminals
Between communication cassette
RS485 and power supply/input/
output/earth terminals
Note3)
Between power supply terminal
and earth terminal