Restriction on using the Add-on cassette
Application cassettes that the version of the FP-X control unit is specified
FP-X Application cassette
Version of control unit
AFPX-DA2
Ver. 2.40 or later
AFPX-A21
AFPX-TC2
AFPX-RTD2
Application cassettes that have restrictions when more than one units are used simultaneously
Current output range
FP-X Application cassette
Quantity
used
Control unit
C14
C30
C60
AFPX-DA2
1
2
Note1)
Note1)
AFPX-A21
1
2
AFPX-DA2 + AFPX-A21
Each 1
Note1)
Note1)
AFPX-DA2 + AFPX-COM5
Each 1
×
Note2)
×
Note2)
×
Note2)
AFPX-A21 + AFPX-COM5
Each 1
×
Note2)
×
Note2)
×
Note2)
AFPX-A21 + AFPX-DA2 + AFPX-COM5
Each 1
×
Note2)
×
Note2)
AFPX-DA2 1unit + AFPX-COM5 1unit
-
×
Note2)
×
Note2)
AFPX-A21 2units + AFPX-COM5 1unit
-
×
Note2)
×
Note2)
Note1) Up to 2 channels can be used for the current output range.
(When using two units, it is possible to use the 2-ch current output range and 2-ch voltage output range.)
Note2) The AFPX-DA2 and AFPX-A21 both cannot be used with the AFP-COM5 (Ethernet).
Voltage output range (When using with the output current of 1 mA or below)
FP-X Application cassette
Quantity
used
Control unit
C14
C30
C60
AFPX-DA2
1
2
AFPX-A21
1
2
AFPX-DA2 + AFPX-A21
Each 1
AFPX-DA2 + AFPX-COM5
Each 1
AFPX-A21 + AFPX-COM5
Each 1
AFPX-A21 + AFPX-DA2 + AFPX-COM5
Each 1
AFPX-DA2 1unit + AFPX-COM5 1unit
AFPX-A21 2units + AFPX-COM5 1unit
Note) In the voltage output range, when using them with the output current at 1 mA to 10 mA, the
condition is the same as the current output range.