Matsushita Electric Works Machine & Vision, Ltd.
ANUP5204 Aicure UV-Curing System
User's Manual

Table of Contents

Questions and Answers

  • A
    Angela WellsAug 4, 2025
    What to do if the Panasonic Industrial Equipment lamp won't come on?
    • A
      Alexis LeeAug 4, 2025
      First, ensure the lamp isn't blackened or broken. Next, check that the lamp's lead wire is securely connected and that the lamp is securely mounted. Also, verify that the magnet position has the same orientation as the system. If none of these steps work, replace the lamp and reset the cumulative use time.
  • R
    richard46Aug 13, 2025
    What to do if the Panasonic Industrial Equipment lamp has reached its lifetime?
    • X
      xduranAug 13, 2025
      If the lamp has reached its lifetime, replace it and remember to reset the cumulative use time of the lamp.
  • J
    John HansenAug 23, 2025
    What to do if the Panasonic Industrial Equipment shutter does not recover?
    • G
      Grace HicksAug 25, 2025
      First, reset the error status. If the error code persists, power the unit off and then back on. Then, check if the main unit cover is removed, the PCB wiring is loose, or if there's any foreign matter in the PCB. If the issue continues, replace the shutter motor.

Summary

Introduction and Safety

Critical Safety Precautions and Hazard Classifications

Details critical safety warnings and hazard classifications for operating the UV-Curing System.

Pre-Use Precautions and Warranty

Component Identification

Operation Panel Controls and Indicators

Details all operation panel buttons, LEDs, display functions, and power controls.

Assembly: Magnet Installation

Assembly: Lamp Installation

Safe Lamp Removal and Installation

Step-by-step guide for safely removing the old lamp and installing a new one.

Assembly: Fiber Unit Installation

System Installation

Operation: Starting and Stopping

Starting System Operation (Lamp On)

Step-by-step guide to powering on the system and turning on the lamp.

Stopping System Operation (Lamp Off)

Procedure for safely turning off the lamp and powering down the system.

Irradiation Modes and Features

Manual Irradiation Operation

Setting UV Intensity

Guide to setting and verifying UV intensity levels before manual irradiation.

Starting and Ending Manual Irradiation

Instructions on how to initiate and terminate manual irradiation using the shutter.

Timer Irradiation Operation

Setting Irradiation Time

Guide to setting and verifying the irradiation time for timer-based operation.

Pattern Irradiation Operation

External Signal Operation

Lamp Replacement Indicator

Lamp Replacement Procedure

Preparation and Safety Precautions

Important safety notes and initial steps before replacing the UV lamp.

Physical Lamp and Lead Wire Replacement

Detailed instructions for replacing the lamp and its associated lead wire.

Safety Measures and Fuses

System Safety Circuit Features

Details safety features preventing cover detachment, overheating, overcurrent, and voltage issues.

Troubleshooting

Resolving Common Issues

Checks and remedies for lamp, shutter, intensity, and overheating problems.

Error Code Diagnosis and Reset

Explanation of error warnings and procedures for resetting error status after addressing causes.

Technical Specifications

Panasonic ANUP5204 Specifications

General IconGeneral
BrandPanasonic
ModelANUP5204
CategoryIndustrial Equipment