47
Aquarea air-to-water heat pumps - Planning and installation manual - 02/2022
Product Description
4
Bi-bloc systems | Aquarea High Performance | J Generation | Single Phase | Heating and Cooling | R32
Single phase (Power to indoor)
Kit KIT‑WC03J3E5 KIT‑WC05J3E5 KIT‑WC07J3E5 KIT‑WC09J3E5
Heating capacity / COP (A +7 °C, W 35 °C) kW / – 3.20 / 5.33 5.00 / 5.00 7.00 / 4.76 9.00 / 4.48
Heating capacity / COP (A +7 °C, W 55 °C) kW / – 3.20 / 2.81 5.00 / 2.72 7.00 / 2.82 8.95 / 2.78
Heating capacity / COP (A +2 °C, W 35 °C) kW / – 3.20 / 3.64 4.20 / 3.18 6.85 / 3.41 7.00 / 3.40
Heating capacity / COP (A +2 °C, W 55 °C) kW / – 3.20 / 2.19 4.10 / 1.99 6.20 / 2.21 6.30 / 2.16
Heating capacity / COP (A -7 °C, W 35 °C) kW / – 3.30 / 2.80 4.20 / 2.59 5.60 / 2.87 6.12 / 2.78
Heating capacity / COP (A -7 °C, W 55 °C) kW / – 3.20 / 1.79 3.55 / 1.71 5.25 / 1.94 5.90 / 1.93
Cooling capacity / EER (A 35 °C, W 7 °C) kW / – 3.20 / 3.52 4.50 / 3.00 6.70 / 3.03 8.20 / 2.72
Cooling capacity / EER (A 35 °C, W 18 °C) kW / – 3.20 / 4.71 4.80 / 4.29 6.70 / 4.72 9.00 / 4.18
ErP data for Space Heating
Average climate
Seasonalenergyefciency(ηs,h) W35 / W55 % 200 / 136 200 / 136 193 / 130 193 / 130
SCOP W35 / W55 5.07 / 3.47 5.07 / 3.47 4.90 / 3.32 4.90 / 3.32
Energy class
1
W35 / W55 A+++ / A++ A+++ / A++ A+++ / A++ A+++ / A++
Warm climate
Seasonalenergyefciency(ηs,h) W35 / W55 % 245 / 165 245 / 165 227 / 160 227 / 160
SCOP W35 / W55 6.20 / 4.20 6.20 / 4.20 5.75 / 4.07 5.75 / 4.07
Energy class
1
W35 / W55 A+++ / A+++ A+++ / A+++ A+++ / A+++ A+++ / A+++
Cold climate
Seasonalenergyefciency(ηs,h) W35 / W55 % 157 / 110 157 / 110 164 / 116 164 / 116
SCOP W35 / W55 4.00 / 2.83 4.00 / 2.83 4.18 / 2.98 4.18 / 2.98
Energy class
1
W35 / W55 A++ / A+ A++ / A+ A++ / A+ A++ / A+
Indoor unit WH‑SDC0305J3E5 WH‑SDC0305J3E5 WH‑SDC0709J3E5 WH‑SDC0709J3E5
Sound pressure Heat / Cool dB(A) 28 / 28 28 / 28 30 / 30 30 / 31
Dimension H x W x D mm 892 x 500 x 340 892 x 500 x 340 892 x 500 x 340 892 x 500 x 340
Net weight kg 42 42 42 42
Water pipe connector Inch R 1¼ R 1¼ R 1¼ R 1¼
A class pump
Number of speeds Variable Speed Variable Speed Variable Speed Variable Speed
Input power (Min / Max) W 30 / 100 33 / 106 34 / 114 40 / 120
Heatingwaterow(∆T=5K.35°C) l/min 9.2 14.3 20.1 25.8
Capacity of integrated electric heater kW 3 3 3 3
Recommended fuse A 15 / 30 15 / 30 15 / 30 15 / 30
Recommended cable size, supply 1 / 2 mm² 3 x 1.5 / 3 x 1.5 3 x 1.5 / 3 x 1.5 3 x 2.5 / 3 x 1.5 3 x 2.5 / 3 x 1.5
Outdoor unit WH‑UD03JE5 WH‑UD05JE5 WH‑UD07JE5 WH‑UD09JE5‑1
Sound power
2
Heat dB(A) 55 55 59 59
Dimension H x W x D mm 622 x 824 x 298 622 x 824 x 298 795 x 875 x 320 795 x 875 x 320
Net weight kg 37 37 61 61
Refrigerant (R32) / CO
2
Eq. kg / t 0.9 / 0.608 0.9 / 0.608 1.27 / 0.857 1.27 / 0.857
Pipe diameter Liquid / Gas Inch (mm) 1/4 (6.35) / 1/2 (12.70) 1/4 (6.35) / 1/2 (12.70) 1/4 (6.35) / 5/8 (15.88) 1/4 (6.35) / 5/8 (15.88)
Pipe length range m 3 ~ 25 3 ~ 25 3 ~ 50 3 ~ 50
Elevation difference (in/out) m 20 20 30 30
Pipe length for additional gas m 10 10 10 10
Additional gas amount g/m 20 20 25 25
Operation range
Outdoor ambient
Heat °C -20 ~ +35 -20 ~ +35 -20 ~ +35 -20 ~ +35
Cool °C +10 ~ +43 +10 ~ +43 +10 ~ +43 +10 ~ +43
Water outlet
Heat °C 20 ~ 60 20 ~ 60 20 ~ 60 20 ~ 60
Cool °C 5 ~ 20 5 ~ 20 5 ~ 20 5 ~ 20
1 Scale from A+++ to D.
2 Sound power in accordance to 811/2013, 813/2013 and EN12102-1:2017 at +7 °C.
Note:
EER and COP calculation is based in accordance to EN14511.