Troubleshooting
6
Setup Program 
fails to complete 
successfully.
• More than 20 minutes have passed since the camera was 
turned on.
Disconnect the AC adaptor from the power outlet, and 
reconnect it again. Set up the camera again.
• Network problems may have occurred during setup.
Confirm that your network is working. Disconnect the AC 
adaptor from the power outlet, and reconnect it again. Then 
set up the camera again.
• Administrator settings are displayed, and setup is incomplete.
After executing factory default by pressing the FACTORY 
DEFAULT RESET button on the side of the camera, set up 
the camera again.
• Multiple camera IP addresses are overlapping.
If you are installing multiple cameras, turn the cameras on 
one by one.
UPnP
TM
 port 
forwarding setup 
fails.
• UPnP
TM
 is disabled on the router.
Enable UPnP
TM
 on the router following the router manual.
• The camera was turned on before the router was turned on.
Turn the router on first, and then turn the camera on.
• The default gateway is not set, or the settings are wrong.
Set the default gateway correctly (see page 36 of the 
Operating Instructions on the CD-ROM).
• The router does not support UPnP
TM
.
Enable port forwarding on your router following the router 
manual.
The camera IP 
address and port 
number have 
been forgotten.
• Clicking [Camera Setup] on the Setup Program displays the 
camera list. The camera list shows the MAC address labeled 
on the rear side. The camera IP address and port number are 
shown next to the MAC address.
The password 
has been 
forgotten.
• Press the FACTORY DEFAULT RESET button to reset the 
camera to default. Set up the camera again.
Problem Cause and Remedy