34 COOLING CAPACITY PERFORMANCE DATA
Model Power
Source
Entering Temperature Air Entering Condeser (°C D.B.)
AIR 25 °C 30 °C 35 °C 40 °C 43 °C
Temperature TC SHC IPT TC SHC IPT TC SHC IPT TC SHC IPT TC SHC IPT
D.B. W.B. kW kW kW kW kW kW kW kW kW kW kW kW kW kW kW
CS-A18BTP 220V, 17 5.21 3.41 1.51 5.00 3.38 1.64 4.71 3.27 1.78 4.35 3.13 1.96 4.10 3.03 2.07
50Hz, 23 19 5.50 2.80 1.60 5.33 2.82 1.74 5.05 2.78 1.89 4.71 2.69 2.07 4.47 2.64 2.20
Single 22 6.00 2.16 1.73 5.84 2.22 1.87 5.57 2.23 2.04 5.22 2.19 2.24 4.97 2.19 2.38
phase 17 5.14 3.93 1.51 4.94 3.88 1.64 4.66 3.75 1.78 4.32 3.61 1.94 4.08 3.48 2.06
25 19 5.50 3.47 1.61 5.31 3.45 1.74 5.03 3.37 1.90 4.68 3.25 2.07 4.44 3.17 2.19
22 6.00 2.73 1.74 5.82 2.76 1.88 5.53 2.74 2.05 4.96 2.56 2.24 4.92 2.63 2.37
17 5.08 4.52 1.52 4.89 4.45 1.63 4.61 4.29 1.78 4.29 4.12 1.93 4.06 4.02 2.05
27 19 5.51 4.08 1.62 5.30 4.03 1.75 5.00 3.90 1.90 4.65 3.77 2.07 4.40 3.65 2.19
22 5.99 3.30 1.75 5.79 3.30 1.89 5.49 3.24 2.05 4.71 2.87 2.23 4.88 3.07 2.36
17 5.07 4.97 1.51 4.89 4.84 1.63 4.41 4.41 1.76 4.32 4.32 1.89 4.11 4.11 1.97
29 19 5.50 4.67 1.61 5.30 4.61 1.74 4.79 4.26 1.88 4.69 4.29 2.02 4.45 4.19 2.10
22 5.97 3.91 1.77 5.77 3.89 1.92 5.22 3.63 2.07 4.95 3.56 2.22 4.87 3.61 2.31
17 5.06 4.96 1.50 4.89 4.89 1.63 4.28 4.28 1.74 4.34 4.34 1.86 4.14 4.14 1.91
32 19 5.49 5.44 1.60 5.30 5.30 1.74 4.65 4.65 1.86 4.71 4.71 1.98 4.49 4.49 2.04
22 5.96 4.88 1.79 5.75 4.83 1.94 5.04 4.33 2.08 5.11 4.55 2.21 4.87 4.43 2.28
TC = Total Cooling Capacity, SHC = Sensible Heat Capacity, IPT = Power Consumption
Model Cooling capacities are based on conditions below.
CS-A18BTP 1 phase, 50Hz, 220V
Cooling capacity Indoor temp. 20°C D.B.
5.0kW Outdoor temp. 7°CD.B.6°CW.B.
Standard air volume 14 m
3
/min
111 [MAICO] Printed in Malaysia