3. Thermostat characteristics during automatic changeover operation
a. Settings at the start of automatic changeover operation
When operation changes from other modes to automatic changeover mode, operation starts at the temperature
characteristics given in the table below.
b. Thermostat characteristic when switching between cooling and heating mode operation
Switching between cooling mode and heating mode operation is carried out as shown in the table below.
However, during automatic changeover operation, the operation will not change within 10 minutes after the thermostat has
switched off, either cooling mode or heating mode.
(The 10 minutes timer will be cancelled when operation is changed to other modes (manually) or when operation stops and
the thermostat turns on.)
c. Thermostat characteristics during cooling mode and heating operation
The thermostat on/off characteristics in both operation modes are given in the table below.
68