MODEL
Unit Main Power
Applicable Voltage
MODEL
Unit Main Power
Applicable
CU-
Phase,
Volts
Hz
Max
Min
CU-
Phase,
Volts
Hz
Max
A24BBP5
1~220 50 242 198
A28BBP8
3N~380 50 418
A28BBP5
1~230
50
253
207
A34BBP8
3N~400
50
440
A34BBP5
1~240
50
264
216
A43BBP8
3N~415
50
457
C24BBP5
A50BBP8
C28BBP5 C28BBP8
C34BBP5 C34BBP8
C43BBP8
C50BBP8
C28BBP6
1~220
60
242
198
C34BBP7
3~220
60
242
C43BBP7
C50BBP7
Indoor and Outdoor Temperature
- Cooling only type / Model 50Hz CU-C24BBP5, CU-C28BBP5, CU-
C28BBP8, CU-C34BBP5, CU-C34BBP8, CU-C43BBP8, CU-C50BBP8
Model 60Hz CU-C28BBP6, CU-C34BBP7, CU-C43BBP7, CU-
C50BBP7
Operating Hz
Indoor Temp. (D.B./W.B.) (°C) Outdoor Temp. (D.B./
W.B.)
Max Min Max
Min
Cooling 50/60 32/23 21/15 43/-
- Heat pump type / Model 50Hz CU-A24BBP5, CU-A28BBP5, CU-
A28BBP8, CU-A34BBP5, CU-A34BBP8, CU-A43BBP8, CU-A50BBP8
Operating Hz
Indoor Temp. (D.B./W.B.) (°C) Outdoor Temp. (D.B./
W.B.)
Max Min Max
Min
Cooling 50 32/23 21/15 43/- -5
/
Heating 50 27/- 16/- 24/18 -
10
10. PIPE LENGTH
CORRECTION OF COOLING CAPACITY AND HEATING CAPACITIES
65