Inlet Air Outdoor Temperature (°C
W.B.)
External
Static
Pressure
(Pa) Air
Volume (m
3
/
min)
Entering
Air Dry
Bulb (°C)
-6 0 6 12
IPT IPT IPT IPT
15 2.49 2.84 3.37 3.98
27 20 2.63 3.02 3.55 4.12
25 2.77 3.20 3.73 4.30
Model Heating capacities are based on
conditions below.
CS-
A34BB4P
Heating
capacity
11.2 kW
3 phase, 50Hz, 400V / Indoor
temperature 20°C D.B. / Outdoor
temperature 7°C D.B. 6°C W.B. /
Standard air volume 27m
3
/min
Inlet Air Outdoor Temperature (°C
W.B.)
External
Static
Pressure
(Pa) Air
Volume (m
3
/
min)
Entering
Air Dry
Bulb (°C)
-6 0 6 12
H.C. H.C. H.C. H.C.
15 8.18 9.80 11.8 13.7
27 20 7.73 9.24 11.2 13.4
25 7.28 8.74 10.6 12.9
85