Time Delay Safety Control
Anti-Freezing Control
Automatic Fan Speed Mode
8.2. Soft Dry Mode Operation
•
The unit starts cooling operation until the room temperature reaches the setting temperature set on the Remote Control, and
then Soft Dry operation will start.
•
During Soft Dry operation, the Indoor Fan operates with Lo speed.
•
Once room temperature reaches below Soft Dry OFF temperature, Indoor Fan, Compressor and Outdoor Fan Stop for 6
minutes.
•
Once the compressor stops, it will not start for 3 minutes during Cooling operation.
•
Same as Anti-Freezing Control for Cooling Mode operation. (For Soft Dry region, 6 minutes waiting is valid during compressor
stops.)
When Automatic Fan Speed is selected at Remote Control during Soft Dry operation.
•
Fan speed rotates at Lo speed.
•
Deodorizing Control.
14