Page #18 background image
CS-A70KE
Operation
Details
1)
Cooling
Mode
Operation
Cooling
in
operation
according
to
Remote
Control
setting.
Time
Delay
Safety
Control
(3
minutes)
*
When
the
compressor
is
stopped
by
Power
Switch,
Remote
Control
or
there
is
a
power
failure,
it
restarts
after
3
minutes
when
the
Power
Switch,
Remote
Control
is
turned
ON
or
the
power
supply
is
resumed.
*
When
the
setting
temperature
is
reached
during
cooling
operation,
the
compressor
stops
and
it
will
not
start
for
3
minutes.
[7
minutes
Time
Saved
Control
|
*
The
compressor
will
start
automatically
if it
has
stopped
for
7
minutes
even
if
the
room
temperature
is
below
the
compressor
ON
temperature.
|
Anti-Freezing
Control
|
Indoor
heat
.
exchanger
*
If
the
temperature
of
the
indoor
heat
exchanger
ferpeenus
falls
continously
below
2°C
for
4
minutes,
the
(°C)
10
compressor
turns
off
to
protect
the
indoor
heat
exchanger
from
freezing.
The
fan
speed
setting
remains
the
same.
*
Compressor
recommences
when
the
indoor
heat
exchanger
temperature
rises
to
10°C
(Recovery).
*
3
minutes
waiting
of
Time
Delay
Safety
Control
is
valid
for
Cooling
Operation.
Compressor
Protection
Control
*
After
the
compressor
starts
for
50
seconds
but
the
outdoor
fan
motor
is
still
OFF,
the
compressor
will
stop
and
restart
automatically.
(Time Delay
Safety
Control
is
valid).
Compressor
OFF
Comp.
operates
for
50
secs.
Compressor
and
=>
sa
=
restarts
Fan
Motor
OFF
(3
minutes
waiting)
*
If
the
above
phenomenon
is
repeated
for
3
times,
the
compressor
will
stop.
¢
The
above
phenomenon
is
reset
when
there
is
a
change
to
heating
mode
or
stopped
by
Remote
Control
Switch.
Compressor
Reverse
Rotation
Protection
Control
°
If
the
compressor
is
operating
continually
for
5
minutes
or
longer
and
the
temperature
difference
between
intake
air
and
indoor
heat
exchanger
is
2.5°C
or
less
for
2
minutes,
compressor
will
stop
and
restart
automatically.
(Time
Delay
Safety
Control
is
valid).
Compressor
*
Compressor
starts
for
=
5
minutes
a>
Compressor
=
|
restarts
*AT
=
2.5°C
for
2
minutes
OFF
|
(3
minutes
waiting)
AT
=
intake
air
temperature
indoor
heat
exchanger
temperature
This
is
to
protect
reverse
rotation
of
the
compressor
when
there
is
a
instantaneous
power
failure.
era
ye

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Panasonic CS-A90KE and is the answer not in the manual?

Panasonic CS-A90KE Specifications

General IconGeneral
BrandPanasonic
ModelCS-A90KE
CategoryAir Conditioner
LanguageEnglish

Related product manuals