Troubleshooting
Guide
Refrigeration
cycle
system
In
order
to
diagnose
malfunctions,
make
sure
that
there
are
no
electrical
problems
before
inspect-
ing
the
refrigeration
cycle.
Such
problems
include
insufficient
insulation,
problem
with
the
power
source,
malfunction
of
a
compressor
and
a
fan.
The
normal
outlet
air
temperature
and
pressure
of
the
refrigeration
cycle
depends
on
various
condi-
tions,
the
standard
values
for
them
are
shown
in
the
table
to
the
right.
Normal
Pressure
and
Outlet
Air
Temperature
(Standard)
\
Se
Gas
pressure
Outlet
air
Be
|
MPa
temperature
e
(kg/cm?G)
(°C)
Cooling
mode
0.4
~
0.6
(4
~
6)
12~16
Heating
mode
1.5
~
2.1
(15
~
21)
36
~
45
*
Condition:
Indoor
fan
speed;
High
Outdoor
temperature
35°C
at
the
cooling
mode
and
7°C
at
the
heating
mode
Difference
in
the
intake
and
outlet
air
temperatures
More
than
8°C
(15
minutes
after
an
operation
is
started.)
at
the
cooling
mode
More
than
14°C
(15
minutes
after
an
operation
is
started.)
at
the
heating
mode
Less
than
8°C
at
the
cooling
mode
Less
than
14°C
at
the
heating
mode
|
Normal
|
e
Measuring
the
air
temperature
difference
Higher
than
specified
Value
of
electric
current
during
operation
e
Measuring
electric
current
during
operation
Lower
than
specified
Gas
side
Cooling
Mode
pressure
Heating
Mode
Clogged
strainer
or
capillary
tube
|
inefficient
compressor
|
Clogged
strainer
or
capillary
tube
Insufficient
refrigerant
—41-