CS-A70KE
Functions
Outdoor
Unit
Protection
Control
*
Outdoor
fan
stops
when
indoor
heat
exchanger
temperature
rises
to
51°C
and
restarts
when
the
indoor
heat
exchanger
temperature
drops
to
49°C.
¢
Compressor
stops
when
indoor
heat
ex-
Overload
Protector
changer
temp.
reaches
65°C
or
above.
(Heating
Operation
only
*
2-stage
OLP
to
protect
the
compressor.
Overload
Protector
will
trip
when
~
High
Temperature
Compressor
Protection
Control
~
High
Current
me
¢
If
the
outdoor
fan
motor
is
not
running
after
(Refer
circuit
diagram
for
OLP
characteristic)
compressor
starts
for
50
secs.,
compressor
will
stop.
(Cooling
and
Soft
Dry
Operation
|
60
Secs.
Forced
Operation
Control
only).
¢
To
protect
compressor
from
reverse
rotation
when
there
is
a
instantaneous
power
failure.
—a
|
¢
Once
the
compressor
is
activated,
it
does
not
stop
for
60
secs.
(Stops
immediate
with
remote
control
stop
signal.)
4-Way
Valve
Control
*
When
the
unit
is
switched
to
“OFF”
during
Heating
Operation,
4-way
valve
stays
at
Heating
position
for
5
minutes.
Deice
Control
¢
To
prevent
frosting
at
outdoor
heat
exchanger.
(Only
for
Heating
Operation)
Outdoor
Fan
Operation
Control
¢
Outdoor
indoor
heat
exchanger
is
sensed
e
|
t
;
by
TRS
(Thermal
Reed
Switch).