EasyManua.ls Logo

Panasonic CS-BZ60ZKE - Cleaning the Air Conditioner

Panasonic CS-BZ60ZKE
60 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6
Cleaning the Air Conditioner
Cleaning has to be carried out at regular intervals to ensure the unit is at optimal
performance. A dirty unit may cause malfunction and you may retrieve “H 99” error
code. Consult an authorised dealer.
Before cleaning, switch off the power supply and unplug the unit.
Do not touch the aluminium n as the sharp parts may cause injury.
Do not use benzine, thinner or scouring powder.
Use soap (
pH 7) or neutral household detergent only.
Do not use water hotter than 40 °C / 104 °F.
Air lters
Once every 2 weeks
• Wash/rinse the lters gently with water to avoid damaging the surface.
• Dry the lters thoroughly under a shade, away from re or direct sunlight.
Replace any damaged lters.
Operating conditions
Use this air conditioner in the temperature range indicated in the table.
Temperature °C (°F)
Indoor Outdoor
DBT WBT DBT WBT
COOL
Max. 32 (89.6) 23 (73.4) 43 (109.4) 26 (78.8)
Min. 16 (60.8) 11 (51.8) -10 (14.0) -
HEAT
Max. 30 (86.0) - 24 (75.2) 18 (64.4)
Min. 16 (60.8) - -15 (5.0) -16 (3.2)
DBT: Dry bulb temperature, WBT: Wet bulb temperature

Related product manuals