1. In order to remove the Cross Flow Fan and Indoor Fan
Motor, Control Board need to be taken out by releasing all
the connectors as indicated below.
a. Release the Earth Wire screw. (Fig. 5)
b. Release the CN-TH connector. (Fig. 5)
c. Release the CN-ION connector. (Fig. 5)
d. Release the CN-SONIC connector. (Fig. 5)
e. Release the CN-STM1 connector. (Fig. 5)
f. Release the CN-STM2 connector. (Fig. 5)
g. Release the CN-DISP connector. (Fig. 5)
h. Pull out the Drain Hose from outlet to remove the
Discharge Grille. (Fig. 5)
2. Release the ION connectors. (Fig. 6)
3. Release the 3 screws. (Fig. 6)
4. By pressing down the hook at the left, you will be able to
remove the Control Board. (Fig. 6)
5. Remove the screw at the Cross Flow Fan. (Fig. 7)
6. Remove the Bearing. (Fig. 8)
7. Remove the screws at the left of the Evaporator. (Fig. 8)
Fig. 5
Fig. 6
Fig. 7
Fig. 8
12.2. Cross Flow Fan and Indoor Fan Motor Removal Procedures
52
CS-C18DKV CU-C18DKV / CS-C24DKV CU-C24DKV

Table of Contents