Do you have a question about the Panasonic CS-C9EKZW and is the answer not in the manual?
| Cooling Capacity | 2.5 kW | 
|---|---|
| Heating Capacity | 3.2 kW | 
| Refrigerant | R32 | 
| Weight (Indoor Unit) | 8 kg | 
| Weight (Outdoor Unit) | 28 kg | 
| Type | Split | 
| Power Supply | 220-240 V, 50 Hz | 
| Indoor Unit Dimensions (W x H x D) | 779 mm x 290 mm x 209 mm | 
| Outdoor Unit Dimensions (W x H x D) | 650 mm x 511 mm x 230 mm | 
Detailed technical specifications for the CS-C9EKZW CU-2C18EKH model.
Detailed technical specifications for the CS-C9EKZW CU-3C20EKH model.
Identifies controls and components within the indoor unit.
Identifies components and features of the outdoor unit.
Details the functions and layout of the remote control.
Provides dimensional drawings and data for the indoor unit and remote control.
Provides dimensional drawings and data for the outdoor unit.
Wiring diagram for the CS-C9EKZW CU-2C18EKH model.
Wiring diagram for the CS-C9EKZW CU-3C20EKH model.
Top view illustration of the indoor unit's printed circuit board.
Top and bottom views of the indicator printed circuit board.
Illustration of the outdoor unit's printed circuit board.
Guidelines for choosing optimal indoor and outdoor unit installation locations.
Visual guide illustrating the installation process for both units.
Instructions specific to the installation of the indoor unit.
Instructions specific to the installation of the outdoor unit.
Details on how to perform and manage cooling operations.
Explanation of the soft dry (dehumidifying) operation mode.
Information on the automatic operation mode and its settings.
General overview of various operational control features.
How to control and adjust the indoor fan speed.
How to adjust the vertical airflow direction.
Details on the quiet operation mode and its settings.
Information on setting and using the timer functions.
How to use the Auto OFF/ON button for servicing and mode selection.
Details on remote control buttons for setting transmission codes and other functions.
A table detailing test modes and their corresponding timer durations.
Diagnosing malfunctions related to the refrigeration cycle.
How system conditions affect pressure and electric current.
Methods for diagnosing compressor malfunctions.
Step-by-step guide to remove indoor unit electronic controllers.
Procedures for removing the indoor fan motor and cross flow fan.
Characteristics and behavior of the thermostat in different modes.
Performance characteristics of the CS-C9EKZW CU-2C18EKH model.
Exploded view and parts list for the CS-C9EKZW model.
Exploded view and parts list for the CU-2C18EKH model.
Exploded view and parts list for the CU-3C20EKH model.