• Heating Characteristic
o Room temperature: 68°F (DBT)
o Operation condition: High fan speed
o Piping length: 24.6 ft
o Compressor Frequency : Fh
85.000
90.000
95.000
100.000
105.000
110.000
115.000
120.000
125.000
14 19 24 29 34 39 44 49 54 59 64 69 74 79
Outdoor Air Temperature (°F)
Outlet Air
Temperature (°F
208 230
2.000
2.500
3.000
3.500
4.000
4.500
5.000
5.500
14 19 24 29 34 39 44 49 54 59 64 69 74 79
Outdoor Air Temperature (°F)
Heating
Capacity (kW)
4.000
4.500
5.000
5.500
6.000
6.500
7.000
7.500
14 19 24 29 34 39 44 49 54 59 64 69 74 79
Outdoor Air Temperature (°F)
Current
(A)
0.300
0.400
0.500
0.600
0.700
0.800
0.900
1.000
14 19 24 29 34 39 44 49 54 59 64 69 74 79
Outdoor Air Temperature (°F)
Gas Side
Low Pressure (MPa)