54
12.9 Timer Control
12.9.1 ON Timer Control
• ON Timer can be set using remote control, where the unit with timer set will start operation earlier than the setting
time. This is to provide a comfortable environment when reaching the set ON time.
• 60 minutes before the set ON time, indoor (at fan speed of Lo-) and outdoor fan motor start operation for 30
seconds to determine the indoor intake air temperature and outdoor air temperature in order to judge the
operation starting time.
• From the above judgment, the decided operation will start operation earlier than the set time as shown below.
12.9.2 OFF Timer Control
• OFF Timer can be set using remote control, the unit with timer set will stop at set time.
12.10 Auto Restart Control
• When the power supply is cut off during the operation of air conditioner, the compressor will re-operate within
three to four minutes (there are 10 patterns between 2 minutes 58 seconds and 3 minutes 52 seconds to be
selected randomly) after power supply resumes.
• This type of control is not applicable during ON/OFF Timer setting.
12.11 Indication Panel
Note:
• If POWER LED is blinking, the possible operation of the unit are Hot Start, during Deice operation, operation
mode judgment, or ON timer sampling.
• If Timer LED is blinking, there is an abnormality operation occurs.