DRY BULB WET BULB
Maximum 89.6 73.4
Indoor Operation Range (Cooling)
Minimum 60.8 51.8
Maximum 109.4 78.8
Outdoor Operation Range (Cooling)
Minimum 60.8 51.8
Maximum 86.0 -
Indoor Operation Range (Heating)
Minimum 60.8 -
Maximum 75.2 64.4
Outdoor Operation Range (Heating)
Minimum 5.0 3.2
1. Cooling capacities are based on indoor temperature of 27°C DRY BULB (80.6°F DRY BULB), 19.0°C WET BULB (66°F WET BULB) and
outdoor air temperature of 35°C DRY BULB (95°F DRY BULB), 24°C WET BULB (75.2°F WET BULB)
2. Heating capacities are based on indoor temperature of 20°C Dry Bulb (68°F Dry Bulb) and outdoor air temperature of 7°C Dry Bulb (44.6°F
Dry Bulb), 6°C Wet Bulb (42.8°F Wet Bulb)
3. Specifications are subjected to change without prior notice for further improvement.