EasyManuals Logo

Panasonic CS-E18DB4EW Service Manual

Panasonic CS-E18DB4EW
200 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #57 background imageLoading...
Page #57 background image
9.2.4. Auto Restart Control
If there is a power failure, operation will automatically be restarted when the power is resumed. It will start with the previous
operation mode and airflow direction. (Timer Delay Safety Control is valid.)
1. Control start conditions
The 24-hour timer must not be set.
The sleep timer must not be set.
Auto start control is not available when timer or sleep mode is set.
2. Description of control
In the case of manual operation, the operation mode, temperature setting, fan speed and airflow direction before the power
is turned off are restored.
In the case of automatic operation, after the power is restored operation starts with the determination of the mode.
While the air conditioner odour clear timer has been set, the setting is cancelled, and operation is transferred to the mode
before the power is turned off.
While the air conditioner odour clear operation (with timer / without timer setting) are being performed, both of these
operations are completed., and operation is transferred to the operation mode prior to these operations.
Example: When the power is turned off during an outdoor unit cooling operation.
57
CS-ME7DKEG CS-ME10DD3 EG / CS-ME10DTEG CS-E15DB4EW

Table of Contents

Other manuals for Panasonic CS-E18DB4EW

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Panasonic CS-E18DB4EW and is the answer not in the manual?

Panasonic CS-E18DB4EW Specifications

General IconGeneral
BrandPanasonic
ModelCS-E18DB4EW
CategoryAir Conditioner
LanguageEnglish

Related product manuals