2. Heating
Note:
a. UP:
•
• •
•
If move from Lo, the fan speed will be shifted to Maximum 1,520 rpm.
•
• •
•
If move from Maximum, the fan speed no change.
•
• •
•
In up zone, 10 rpm is added for every 10s until Maximum 1,520 rpm.
b. DOWN:
•
• •
•
The fan speed will be decreased one step every 10 sec. until Minimum 1,270 rpm.
c. Current Output Fixed:
•
• •
•
Maintain at present fan speed.
d. Instantaneous Maximum:
•
• •
•
Fan speed will be increased to maximum auto fan speed.
e. Temperature in ( ) is for Powerful Mode operation.
C. Fan Motor Control
1. Motor specification
Phase control motor
D. Deodorizing Control
i. Control condition
Control at cooling/dry operation and auto fan speed setting.
No Deodorizing Control is performed during ON timer standby operation and during Anti-freezing control prevention.
ii. Operation
The odor status is arranged as below and it is shifted as follows.
* When COMP is ON 1
→
2
→
3
(Shift to 4 when COMP is OFF)
* When COMP is OFF 4
→
5
→
6
→
7
→
6
←→
7
(Shift to 1 when COMP is ON)
* Start from 4 if the Thermostat is OFF during the start operation.
68
CS-ME7DKEG CS-ME10DD3 EG / CS-ME10DTEG CS-E15DB4EW