• ECO Patrol Demo Mode
- Press “Set” button continuously for 15 seconds by using pointer during Air Conditioner is OFF condition to enter internal
setting mode.
- Press “Timer Decrement” button to select “EC demo”.
- Press “Timer Set” button to toggle ECO Patrol Demo mode.
- Short “beep”: Turn ON ECO Patrol Demo mode.
- Long “beep”: Turn OFF ECO Patrol Demo mode.
Control details:
• During ECO Patrol Demo mode, operation LED ON and horizontal vane will set to Auto Swing.
• When Hi activity judge, Fan speed change to Hi Fan and ECO Patrol LED ON.
• When Lo activity judge, Fan speed change to Lo Fan and ECO Patrol LED OFF.
• No setting temperature adjustment.
• During ECO Patrol operation, the internal setting temperature and fan speed are adjusted in order to provide comfort and energy
saving.
• ECO Patrol Start condition.
- Press ECO Patrol button to select ECO1 and ECO2.
• ECO Patrol Stop condition.
- Press ECO Patrol button again.
- OFF Timer activates.
- Press OFF/ON button to turn off the air conditioner.
- Press AUTO OFF/ON button to turn off the air conditioner.
- Press POWERFUL/QUIET button.
- Press Mild Dry Cooling button.
• ECO Patrol operation could ON when any of the following conditions is fulfilled:
• During forced cooling or forced heating operation.
• During e-ion or individual patrol operation.
•
• Power Failure
- ECO Patrol operation will be resuming after recovered from power failure.
• Timer Operation
- When unit is turn on by ON Timer and ECO Patrol operation is ON during previous operation before OFF, ECO Patrol
operation will not be ON automatically.
- When unit is turn on by ON Timer and ECO Patrol operation is OFF during previous operation before OFF, ECO Patrol
operation will not be ON automatically.