166
18.1.5 CU-E18NKR
Cooling Characteristic
[Condition] Indoor temperature: 27/19°C
Remote condition: High fan speed
Comp. Hz: F
c
Piping Length: 5m
13.200
13.700
14.200
14.700
15.200
15.700
16.200
16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46
Outdoor Air Temperature (°C)
Outlet Air
Temperature (°C
230 240
4.200
4.700
5.200
5.700
6.200
16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46
Outdoor Air Temperature (°C)
Cooling
Capacity (kW)
3.600
4.100
4.600
5.100
5.600
6.100
6.600
7.100
16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46
Outdoor Air Temperature (°C)
Current
(A)
0.870
0.890
0.910
0.930
0.950
0.970
16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46
Outdoor Air Temperature (°C)
Gas Side Piping
Pressure (MPa