86 
13.10  Indication Panel  
LED POWER  TIMER  POWERFUL  nanoe-G AUTO COMFORT  QUIET 
Color Green  Orange  Orange  Blue  Green  Green 
Light ON  Operation ON  Timer Setting ON 
POWERFUL Mode 
ON 
nanoe-G ON 
AUTO COMFORT 
ON 
QUIET Mode
ON 
Light OFF  Operation OFF Timer Setting OFF 
POWERFUL Mode 
OFF 
nanoe-G OFF 
AUTO COMFORT 
OFF 
QUIET Mode 
OFF 
 
Note: 
  If POWER LED is blinking, the possible operation of the unit are Hot Start, during Deice operation, operation 
mode judgment, or ON timer sampling. 
  If Timer LED is blinking, there is an abnormality operation occurs. 
 
13.11 nanoe-G Operation 
  This operation provides clean air by producing great amount of negative ions and distribute through the 
discharge airflow to capture or deactivate molds, bacteria or viruses. 
 
  nanoe-G operation start condition 
o  During unit running at any operation mode, if nanoe-G operation is activated, combination operation 
(operation mode + nanoe-G operation) starts. 
o  During unit is OFF, if nanoe-G operation is activated, nanoe-G individual operation starts. 
 
  nanoe-G operation stop condition 
o  When OFF/ON button is pressed to stop the operation. 
o  When nanoe-G button is pressed. 
o  When OFF Timer activates. 
 
  nanoe-G operation pause condition 
o  When indoor fan stop (during deice, odor cut control, thermostat off, etc.). nanoe-G operation resume after 
indoor fan restarts. 
o  When indoor intake temperature ≥ 40°C. nanoe-G operation resume after indoor intake temperature ≤ 40°C 
continuously for 30 minutes. 
 
 Indoor fan control 
o  During any operation mode combines with nanoe-G operation, fan speed follows respective operation mode. 
However, nanoe-G system enabled when fan speed ≥ 500rpm to ensure proper negative ion distribution, 
nanoe-G system disabled when fan speed < 500 rpm. 
o  During nanoe-G individual operation, only Auto Fan Speed and no Powerful operation is allowed. Even if Fan 
Speed button is pressed, no signal is sent to the unit and no change on remote control display. Auto Fan 
Speed for nanoe-G operation changes from SHi to Hi after 4 hours of operation. 
 
  Airflow direction control 
o  During any operation mode combines with nanoe-G operation, airflow direction follows respective operation 
mode. 
o  During nanoe-G individual operation, only Auto Air Swing is allowed. Even if Air Swing button is pressed, no 
signal is sent to the unit and no change on remote control display. 
 
 Timer control 
o  When ON Timer activates when unit stops, previous operation resumes and restored last saved nanoe-G 
operation status. 
o  When ON Timer activates during any operation, no change on current operation. 
o  When OFF Timer activates during any operation, all operation stops and the latest nanoe-G operation status 
is saved. 
 
 Indicator 
o  When nanoe-G starts, nanoe-G indicator ON.