Indoor Unit
Automatic Operation Switch
• Press for < 5s to run Automatic Operation.
(Used when the remote control cannot be used.)
• Press continuously for 5s and < 8s to run
Forced Cooling Operation.
• Press continuously for 8s and < 11s to run
Forced Heating Operation.
• Press continuously for 11s and < 16s to
change different remote controlling
setting (A↔B Mode).
• Press continuously for 16s or < 21s to
switch OFF / ON Remote Control
Receiving Sound or H14 Abnormality
Detection Mode.
Operation Indication Lamps (LED)
Sleep Mode
Five Operation Modes
• Automatic, Heating, Cooling, Soft Dry
and Fan Operation.
Delay ON Timer and OFF Timer
Powerful Mode
• For quick cooling or heating.
•
POWER
(Orange) .....
Lights up during
MONITOR
compressor operation.
•
POWER
(Green) ........ Lights up in
operation, blinks in
Automatic Operation
Mode judging and
Hot Start operation.
•
TIMER
(Orange) ....... Lights up in Timer
Setting.
Blinks in Self
Diagnosis Control.
•
SLEEP
(Orange)........ Lights up in Sleep
Mode Operation.
•
POWERFUL
(Orange).. Lights up when
Powerful Mode is
selected.
Automatic and 5 Manual Indoor
Fan Speeds
Automatic and 5 Manual Vertical
Airflow Directions
Automatic and 5 Manual Horizontal
Airflow Directions
Automatic Restart Control
• Operation is restarted after power failure
at previous setting mode.
Microcomputer-controlled Room
Temperature Control
4