EasyManuals Logo
Home>Panasonic>Air Conditioner>CS-E9BKP

Panasonic CS-E9BKP Service Manual

Panasonic CS-E9BKP
89 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #6 background imageLoading...
Page #6 background image
3 Product Specifications
Unit CS-E9BKP CU-E9BKP5
Cooling Capacity kW
kcal/h
2.6 (0.60 - 3.00)
2,240 (520 - 2,580)
Heating Capacity kW
kcal/h
3.6 (0.60 - 5.00)
3,100 (520 - 4,300)
Moisture Removal l/h
Pint/h
1.6
(3.4)
Power Source Phase
V
Cycle
Single
230
50
Airflow Method OUTLET
INTAKE
SIDE VIEW TOP VIEW
Air Volume Indoor Air (Lo) m
3
/min (cfm) Cooling; 6.5 (231)
Heating; 7.1 (249)
Indoor Air (Me) m
3
/min (cfm) Cooling; 8.1 (286)
Heating; 8.8 (312)
Indoor Air (Hi) m
3
/min (cfm) Cooling; 9.9 (350)
Heating; 10.6 (374)
dB (A) Cooling; High 39, Low 26 Cooling; 46
Heating; High 40, Low 27 Heating; 47
Noise Level
Power level dB Cooling; High 50 Cooling; High 59
Heating; High 51 Heating; High 60
Electrical Data Input W Cooling; 700 (115 - 880)
Heating; 900 (110 - 1,400)
Running Current A Cooling; 3.3
Heating; 4.0
EER W/W (kcal/hw) Cooling; 3.71(3.20)
COP W/W (kcal/hw) Heating; 4.00 (3.44)
Starting Current A 4.00
Piping Connection Port
(Flare piping)
inch
inch
G ; Half Union 3/8
L ; Half Union 1/4
G ; 3-way valve 3/8
L ; 2-way valve 1/4
Pipe Size
(Flare piping)
inch
inch
G (gas side) ; 3/8
L (liquid side) ; 1/4
G (gas side) ; 3/8
L (liquid side) ; 1/4
Drain
Hose
Inner diameter mm 12
Length m 0.7
6
CS-E9BKP CU-E9BKP5 / CS-E12BKP CU-E12BKP5

Other manuals for Panasonic CS-E9BKP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Panasonic CS-E9BKP and is the answer not in the manual?

Panasonic CS-E9BKP Specifications

General IconGeneral
BrandPanasonic
ModelCS-E9BKP
CategoryAir Conditioner
LanguageEnglish

Related product manuals