9
English
The following symptoms do not indicate malfunction.
Symptom Cause
Mist emerges from indoor unit. Condensation effect due to cooling process.
Water owing sound during operation. Refrigerant ow inside the unit.
The room has a peculiar odour. This may be due to damp smell emitted by the wall,
carpet, furniture or clothing.
Indoor fan stops occasionally during automatic
fan speed setting.
This helps to remove the surrounding odour.
Operation is delayed a few minutes after
restarting.
The delay is a protection to the unit’s compressor.
Outdoor unit emits water/steam. Condensation or evaporation occurs on pipes.
TIMER indicator is always on. The timer setting repeats daily once set.
Power indicator blinks during operation and the
indoor fan is stopped.
The unit is in defrost mode, and the melted frost is
drained from the outdoor unit.
Indoor fan stops occasionally during heating
operation.
To avoid unintended cooling effect.
POWER indicator blinks before the unit is
switched on.
This is a preliminary step in preparation for the
operation when the ON timer has been set.
Cracking sound during operation. Changes of temperature caused the expansion/
contraction of the unit.
Check the following before calling for servicing.
Symptom Check
Operation in HEAT/COOL mode is not working
ef ciently.
Set the temperature correctly.
Close all doors and windows.
Clean or replace the lters.
Clear any obstruction at the air inlet and air outlet vents.
Noisy during operation. Check if the unit has been installed at an incline.
Close the intake grille properly.
Remote control does not work.
(Display is dim or transmission signal is weak.)
Insert the batteries correctly.
Replace weak batteries.
The unit does not work. Check if the circuit breaker is tripped.
Check if timers have been set.
The unit does not receive the signal from the
remote control.
Make sure the receiver is not obstructed.
• Certain uorescent lights may interfere with signal
transmitter. Please consult authorised dealer.
Troubleshooting
NON SERVICEABLE CRITERIAS
TURN OFF POWER SUPPLY then please
consult authorised dealer under the
following conditions:
Abnormal noise during operation.
Water/foreign particles have entered the
remote control.
Water leaks from Indoor unit.
Circuit breaker switches off frequently.
Power cord becomes unnaturally warm.
Switches or buttons are not functioning
properly.
The unit stops and the TIMER indicator blinks.
Write down error code
at indicator.
If the error code does not
appear at the indicator.
Press to
retrieve
error code,
then write
down the
error code
at indicator.
TIMER
SET
CANCEL
ON
OFF
1
2
3
CHECK CLOCK RESET
Turn the unit off and reveal the error code to authorised
dealer.
For certain errors, you may restart the unit for limited
operation with 4 beeps when operation starts.
Cleaning instructions / Troubleshooting

Other manuals for Panasonic CS-E9GFEW

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Panasonic CS-E9GFEW and is the answer not in the manual?

Panasonic CS-E9GFEW Specifications

General IconGeneral
BrandPanasonic
ModelCS-E9GFEW
CategoryAir Conditioner
LanguageEnglish

Related product manuals