10.5.12. As to making the inspection after completion of work fully understood
At the time when the work has been completed, measure and record the characteristics of test run without fail and keep the mea-
suring date, etc.
Carry out the measurement regarding room temperature outside air temperature, suction and air discharge temperatures, wind
velocity, wind volume, voltage current, presence of abnormal vibration, operating pressure, piping temperature, compressive
pressure, airtight pressure as items to be measured.
As to the structure and appearance, check following items.
10.5.13. As to delivery to the customer
Request the customer to operate this air conditioner viewing instruction manual come with indoor unit in practice and explain
how to operate.
Deliver the instruction manual to the customer without fail.
Short circuit of the blow-out air
Smooth flow of the drain
Reliable thermal insulation
Leakage of refrigerant
Mistake in wiring
Reliable connection of the grand wire
Looseness in terminal screw, fastening torque
M3... 69-98N.cm {7-10kgf.cm} M4... 157-196N.cm {16-20kgf.cm}
M5... 196-245N.cm {20-25kgf.cm}

Table of Contents

Other manuals for Panasonic CS-F14DB4E5

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Panasonic CS-F14DB4E5 and is the answer not in the manual?

Panasonic CS-F14DB4E5 Specifications

General IconGeneral
BrandPanasonic
ModelCS-F14DB4E5
CategoryAir Conditioner
LanguageEnglish

Related product manuals