EasyManuals Logo

Panasonic CS-F14DD3E5 Service Manual

Panasonic CS-F14DD3E5
148 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #100 background imageLoading...
Page #100 background image
100
12.2. During twin operation
System example
1. The main power is turned on while the transmission wires between the indoor units are not connected.
(open circuit at A or B)
Symptom
Remote control unit: “check” flashes
Error code: F30-01 (connected indoor capacity error)
Indoor unit No. 1: LED1 on P.C.B flashes
Indoor unit No. 2: no power supply
Outdoor unit: LED6, 7 on P.C.B flashes (connected indoor capacity error)
2. The main power is turned on while the transmission wires between the indoor units are not connected.
(open circuit at section C)
Symptom
Remote control unit: “check” flashes
Error code: F30-01 (connected indoor capacity error)
Indoor unit No. 1: LED1 on P.C.B flashes
Indoor unit No. 2: no power supply
Outdoor unit: LED5, 6 on P.C.B flashes (connected indoor capacity error)
3. The main power is turned on and the connection wire is all ok.
If operation starts in this condition, combination of the J50DBE8 outdoor unit and F24DB4E5 indoor unit will result in abnormal
operation.
Symptom
Remote control unit: “check” flashes
Error code: F30-01 (connected indoor capacity error)
Indoor unit: LED1 on P.C.B flashes
Outdoor unit: LED6, 7 on P.C.B flashes

Table of Contents

Other manuals for Panasonic CS-F14DD3E5

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Panasonic CS-F14DD3E5 and is the answer not in the manual?

Panasonic CS-F14DD3E5 Specifications

General IconGeneral
BrandPanasonic
ModelCS-F14DD3E5
CategoryAir Conditioner
LanguageEnglish

Related product manuals