The address settings for group control (air conditioner Nos. 1 to 16) can be reset automatically.
1. When operation is stopped, press for 5 seconds, continue the TEST RUN switch to display “00” (will be LOCAL MODE).
2. Press the UP (TEMP) DOWN (TEMP) switch to display 10.
3. Press the SELECT switch to display “000”. It would blink.
4. Press the UP (TIMER) DOWN (TIMER) switch to display “001”. It would blink.
5. Press the SET switch.
The temperature detection thermistor can be switched between the thermistor at the indoor unit and the thermistor at the remote
controller. However, do not switch to the remote controller thermistor if using two remote controllers.
1. When operation is stopped, press for 5 seconds, continue the TEST RUN switch to display “00” (will be LOCAL MODE).
2. Press the UP (TEMP) DOWN (TEMP) switch to display 11.
3. Press the SELECT switch to display “000”. It would blink.
4. Press the UP (TIMER) DOWN (TIMER) switch to choose display “000” or “001”.
“000”... Indoor unit setting (factory default)
“001”... Remote controller setting
5. Press the SET switch. (Be sure to press the SET switch so that normal operation mode can be resumed.)
Repeat the procedure in steps (1) to (5) to change the setting again.
Automatic address resetting for group control
Switching the thermistor

Table of Contents

Other manuals for Panasonic CS-F14DD3E5

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Panasonic CS-F14DD3E5 and is the answer not in the manual?

Panasonic CS-F14DD3E5 Specifications

General IconGeneral
BrandPanasonic
ModelCS-F14DD3E5
CategoryAir Conditioner
LanguageEnglish

Related product manuals