[Manual setting]
10.7.5. Emergency operation
If you do not have the wireless remote controller (because the batteries are weak, or some other reason prevents the wireless
remote controller from being used), emergency operation can be carried out at receptor unit.
Press the AUTO switch to start emergency operation.
Press the AUTO switch once more to stop emergency operation.
Press the AUTO switch continue 5 second to start cooling operation.
Again press the AUTO switch continue 5 second to start heating operation.
The setting temperature, fan speed and louver control will be fixed at the settings shown in the table below.
While the indoor unit is running, the OPERATION indicator on the receptor unit will illuminate, and it will switch off when the
indoor units stops.
Heating operation is not available for indoor units which are for cooling only. (If set to HEAT, the setting will change to FAN
instead.)
Operation mode Fan speed Louver
Cooling Hi Previous setting
Heating Hi Previous setting
Instructions for users