13.4.2. Heating performance
13.4.2.1. CS-F24DD2E5 CU-B24DBE5
Model Heating capacities are based on conditions
CS-F24DD2E5 CU-B24DBE5 Single phase, 50Hz, 230V
Heating capacity Indoor temp. 20°C D.B.
7.1 kW Outdoor temp. 7°C D.B. 6°C W.B.
Standard air volume 22 m
3
/min
13.4.2.2. CS-F28DD2E5 CU-B28DBE5
Model Heating capacities are based on conditions
CS-F28DD2E5 CU-B28DBE5 Single phase, 50Hz, 230V
Heating capacity Indoor temp. 20°C D.B.
8.0 kW Outdoor temp. 7°C D.B. 6°C W.B.
Standard air volume 22 m
3
/min
13.4.2.3. CS-F28DD2E5 CU-B28DBE8
Model Heating capacities are based on conditions
CS-F28DD2E5 CU-B28DBE8 3 phase, 50Hz, 400V
Heating capacity Indoor temp. 20°C D.B.
8.0 kW Outdoor temp. 7°C D.B. 6°C W.B.
Standard air volume 22 m
3
/min
119