– 21 –
MAC9509078C2
CS-G93KE
Operation Details
When the compressor is in operation, the deodorizing status starts from 1 2.
When the compressor stops operation, the deodorizing status starts from 3 4 5.
When the compressor stops operation, indoor fan stops for 330 seconds.
B. Deodorizing Control
This control is available during automatic fan speed for Cooling and Soft Dry Operation. It is not available
during anti-freezing control.
C. Sensible Heat Control
This control is to improve the feeling in high fan speed and low operation frequency. When the operation
frequency is less than 33Hz (CU-G93KE) or 36Hz (CU-G123KE), the fan speed will reduce. When the
operation frequency is increased to 40Hz (CU-G93KE) or 49Hz (CU-G123KE) continuously for 5 minutes,
the fan speed will resume to normal condition. (During Cooling operation).
Fan Speed
Compressor
ON
ON ON
Deodorizing Status
Compressor
ON
Time (second)
Fan Speed
1
40
OFF
3
330
OFF
2
SLo
4, 5, 4, 5,…
………
………
ON
1
40
OFF
OFF
4
30
SLo
5
60
OFF
ON
OFF
OFF
OFF
Untitled-3 6/20/00, 5:03 PM21