Operation Details
• Compressor OFF temperature = compressor ON temperature.
• The operation frequency changes every 30 seconds.
• When the difference of the intake air temperature and Internal setting temperature is –1.5°C or more, compressor will operate at Fh
continuously for 3 minutes and then change over to Fhmax.
• The compressor stops when the intake air temperature reaches 1.5°C above internal setting temperature and continues for 3 minutes.
• When the compressor stops, it will not start operation for 3 minutes. (Time Delay Safety Control)
• When the intake air temperature decreases to the compressor ON temperature, the compressor starts immediately.
• When the compressor stops, the outdoor fan motor stops 30 seconds later.
CS-G123KE
+1.5
+1.0
+0.5
0
–0.5
–1.0
–1.5
Heating Operation
Remote Control Setting Temp.
Intake air temperature –
Internal setting temperature
Compressor OFF
Internal setting temp.
Outdoor air temperature
Compressor Operation Frequency (Hz)
Stabilized Period
21°C ~ 30°C
16°C ~ 20°C
Transition Period
16°C ~ 30°C
Comp Off
16
16
22
64
74
86
90 (Fh) or
115 (Fhmax)
Comp Off
16
22
27
36
44
64
90 (Fh) or
115 (Fhmax)
–1°C and
above
Comp Off
16
27
36
44
64
74
90 (Fh) or
115 (Fhmax)
Less than
–1°C
Comp Off
16
22
27
36
44
64
90 (Fh) or
115 (Fhmax)
–1°C and
above
Comp Off
16
22
27
36
44
64
90 (Fh) or
115 (Fhmax)
Less than
–1°C